A 54-inch (1380–1400 mm) barn exhaust fan turns at roughly 500 rpm and needs about 14 Nm at the shaft. That is the duty our HSE-PM38H075-140N05-S4X was built around: 0.75 kW, 500 rpm, 14 Nm, IE5, IP66, mounted directly on the impeller hub with no belt. A 48-inch fan sits closer to 700 rpm and 15 Nm, which moves you up to the HSE160 frame; a 61-inch fan wants about 25 Nm at 580 rpm.
Those numbers come from the selection table we give fan manufacturers, and they hold for most tunnel-ventilated broiler, layer and pig houses. Where they stop holding is the subject of most of this page: houses with heavy pad resistance or long tunnels, farms with single-phase supply, and buildings that get washed down with a pressure hose between flocks.

Start from the impeller, not from the old motor’s nameplate
Most retrofit inquiries we receive start the same way: “we have 1.1 kW motors, please quote 1.1 kW EC motors.” It is a reasonable request and almost always the wrong one.
A typical older 54-inch fan has a four-pole induction motor running near 1450 rpm and a belt that brings the impeller down to 450–550 rpm. The 1.1 kW on the nameplate is sized for the motor’s own speed. Take the belt away and drive the impeller directly, and the motor now has to deliver the impeller’s torque at the impeller’s speed. Torque is power divided by speed (T = 9550 × P / n), so a direct-drive motor at 500 rpm and a belted motor at 1450 rpm with the same kW rating are very different machines.
Our HSE140 frame shows it: its 0.75 kW versions run from 2.4 Nm at 3000 rpm to 14 Nm at 500 rpm, each with its own winding, as described in inside an industrial EC fan motor. Fit the 1500 rpm version to a 54-inch impeller and it will trip on over-current at start-up, or crawl well below the speed the fan curve assumes.
So we select by impeller speed first, then torque at that speed with a 15–20 % margin, and only then power; the method from a fan curve is in our guide to sizing an EC fan motor from the fan curve. If you only know the fan diameter, the table below is a reasonable first pass.
Fan size to motor: the reference table
| Fan size | Typical speed | Shaft torque needed | Model | Rating |
| 48″ (1220 mm) | ~700 rpm | ~15 Nm | HSE-PM38H110-160N07-S4X | 1.1 kW / 700 rpm / 15 Nm |
| 54″–55″ (1380–1400 mm), standard | ~500 rpm | ~14 Nm | HSE-PM38H075-140N05-S4X | 0.75 kW / 500 rpm / 14 Nm |
| 54″–55″, low static pressure | ~560 rpm | ~10.5 Nm | HSE-PM38H055-140N05-S4X | 0.55 kW / 560 rpm / 10.5 Nm |
| 60″–61″ (1530–1550 mm) | ~580 rpm | ~25 Nm | HSE-PM38H150-160N05-S4X | 1.5 kW / 580 rpm / 25 Nm |
| 60″–61″, high static pressure | ~750 rpm | ~28 Nm | HSE-PM38H220-160N07-S4X | 2.2 kW / 750 rpm / 28 Nm |
| 54″–55″, farm with 220 V only | ~460 rpm | ~15.5 Nm | HSE-PM22H075-160N04-S4X | 0.75 kW / 460 rpm / 15.5 Nm |
All six are inner-rotor motors with the drive built on, rated IE5 and IP66, class F insulation, S1 continuous duty. The 380 V models run on three-phase supply; other voltages from 110 to 480 VAC, single- or three-phase, can be built for a project.
Two cautions about using a table like this.
Static pressure moves the answer more than people expect. A 54-inch fan on the end wall of a short house with dry pads might need 10 Nm. The same fan at the end of a 150-meter tunnel house in summer, pulling through wet pads and a dusty insect screen, can need noticeably more, and fan torque rises with the square of speed: push a fan that needed 12 Nm at 500 rpm up to 560 rpm and it needs about 15 Nm. If the fan maker can give you the torque at the highest pressure point on the curve, size for that.
The other caution is about the 220 V row. Many older pig and poultry sites in Southeast Asia and Latin America only have single-phase power at the fan wall. The HSE-PM22H075-160N04-S4X covers exactly this case. It saves the cost of running three-phase cable to every fan, which on a large site can be more than the price difference between motors.

Wash-down, ammonia and condensation
Why a pressure-washed barn needs IP66, and why ammonia and condensation sit outside the IP code, is set out in our EC fan motor selection guide for livestock, greenhouses and industrial ventilation. All our inner-rotor and disc motors are IP66, while our external-rotor motors are IP54 and we do not recommend them for washed houses. In closed pig and layer houses the fasteners are usually the first thing ammonia ruins; they seize, and the next maintenance job turns into a grinding job, so name a known ammonia problem at the inquiry stage and the coating, seals and fasteners can be specified for it.
Barns also get more condensation inside sealed motors than most buildings, because of humid air, cooling pads, large day-night swings and weeks of idle fans between flocks. Two cheap habits prevent most of the trouble: run the fans for 10–15 minutes once a month while the house is empty, and measure insulation resistance before re-energizing after a long stop. On an integrated EC motor, check the drive manufacturer’s test procedure first; a megger applied to the wrong terminals can damage the electronics.
Where the energy saving comes from in a livestock house
People expect the saving to come from motor efficiency, and some of it does. An IE5 permanent magnet motor has no rotor current and no slip loss, which matters most on a slow, lightly loaded fan. But in a poultry or pig house the larger saving comes from speed control.
A broiler house needs only minimum ventilation in winter and every fan at full speed in summer, and conventional houses cover that range by switching whole fans on and off. With EC motors the controller runs more fans at part speed instead: by the cube law, eight fans at 50 % speed move the same air as four at full speed for about a quarter of the power, though static pressure, pads and inlets soften that in practice.
To estimate it for a specific house you need installed fan power, operating hours, the average load across the year and the electricity tariff; our energy savings and payback calculator takes those inputs. Measure the load rather than guessing it; overestimating it is the usual reason a projected payback does not materialize.

Connecting the motors to the house controller
Speed control only saves energy if something tells the fans to slow down. All our EC fan motors accept a 0–10 V analog signal and RS485 / Modbus RTU as standard.
Most poultry and pig climate controllers have 0–10 V outputs for variable-speed fans, so for a retrofit this is usually the simplest connection: one shielded signal pair per fan or per group of fans, with the shield earthed at one end only and the cable kept away from the power cables.
RS485 / Modbus is worth the extra commissioning time on larger houses and on new builds. Beyond setting speed, the controller can read each motor’s actual speed, current, DC bus voltage, drive temperature and fault codes. A fan whose current is creeping up week by week usually has a dirty screen, a slipping shutter or a bearing on its way out, and it is far cheaper to find that from the office than after the motor trips on a 35 °C afternoon. Wiring details, termination and how many motors to put on one bus segment are covered in our 0–10 V and Modbus wiring guide.
Notes for fan manufacturers and retrofit contractors
If you build barn fans, or you are converting an existing fan line, these are the mechanical points that decide whether a conversion is a motor swap or a redesign.
The HSE140 frame has an outside diameter of Φ162 mm with a Φ15 mm shaft; the HSE160 frame is Φ193 mm with a Φ24 mm shaft. Both mount on a foot or slide-rail bracket, which in most box and cone fans lets the existing frame and impeller stay in place. There is no B14 face flange on these two frames. Check the hub bore and keyway against the shaft before anything else, and note the direction of rotation viewed from the shaft end: a barn fan running backwards trips nothing, and nobody notices until the house gets warm. It is one of the most common faults after a conversion.
On the electrical side, measure the voltage at the fan wall, not at the panel, and check three-phase unbalance; keep it under 2 % at the motor terminals. Long runs on older farms often lose more voltage than anyone expects. Reset the overload protection to the new motor’s nameplate current, which is lower than the old induction motor’s for the same duty, and do not forget the control cable: an EC motor wired for power but not for signal will either run at a default speed or report signal loss.
The drive on these motors is cooled by the fan’s own airflow over its heatsink. In an exhaust fan that is automatic, but if you are designing a new housing, keep the drive in the air stream.
For a new fan design we need only three numbers to propose a motor: supply voltage, power and speed. If you can add the fan curve, the shaft and mounting interface and the expected annual volume, we can check torque margin and fit at the same time. Samples take 30 working days and series production 40 working days; for custom ratings the reference minimum order is 500 pieces. Warranty is 18 months.
Questions farm and fan buyers ask us
Is it worth converting fans that only run in summer?
Often not on energy alone. A fan that runs a few hundred hours a year will take a long time to pay back the motor. The fans that pay back fastest are the ones that run most hours: minimum-ventilation fans in winter and the first stages in spring and autumn. Convert those first.
What if the house has no 0–10 V output on the controller?
Depending on the model, the motor can also take a potentiometer or up to five preset speeds through its digital inputs, so a simple manual or timer-based setup is possible. For automatic temperature-based control, most farms add a controller with analog outputs or move to Modbus.
Send us your fan data
Tell us the fan diameter, the supply voltage at the fan wall and, if you have it, the fan curve or the old motor’s nameplate. We will come back with a model, the torque margin at your duty point and the catalogue data. Email sales@volcanoelectric.com, message us on WhatsApp at +86 136 1018 9327, or use the form on our contact page. The full inner-rotor range is on the HSE140/HSE160 product page.